Instrument Sharing
1、Terahertz Spectrometer
Brand Model:TeraPulse4000

Specifications: Dynamic range >50dB, Frequency range up to 4THz, Scanning speed > 5Hz, with independent complete transmission, reflection, ATR measurement module
Charge: 400 RMB/ hour
2、 Gas Chromatography Mass Spectrometry
Brand Model: Agilent:GC-MS 7820A-5977E
 
(一)Mass Spectrometry:
    1、Mass Spectrometry Performance 
        1)、Fully automatic tuning
        2)、The number of mass range: 1.6-1050amu, 0.1amu increments
        3)、Resolution: single mass count
        4)、The quality axis stability: not less than 0.10amu / 48 hours
        5)、sensitivity:
            Full scan sensitivity (electron bombardment source): 1pg OFN, the signal / noise ratio> 400 ︰ 1 
            Selection detection (electron bombardment source): 20fg OFN, the signal / noise ratio> 10 ︰ 1
        6)、Maximum scan rate: 12500u / s 1 ms SIM dwell time
        7)、Dynamic range: full dynamic range of 106
        8)、Selection detection mode: desirable 100 groups of ions, 60 ions / group
        9)、With traction detection function
    2、Ion Source 
        1)、Made of completely inert material (non-coated, non-stainless steel)
        2)、EI source with two long-term filament, can be automatically switched by the software
        3)、Ionization energy: 5-241.5eV
        4)、Ion source temperature: independent temperature control, 150-350?C adjustable
    3、The Quality Analyzer: 
        1)、The whole quartz gold-plated hyperboloid quadrupole
        2)、Specially designed Turner-Kruge lens, can improve the sensitivity, protect the quadrupole,,
        3)、Can be independent temperature control, the maximum temperature can be ≧ 200?C
    4、The Detector: long-term high-energy electronic multiplier
    5、The Vacuum System: high-performance molecular turbo pump
(二)Chromatographic:
1. Column oven
        1)Size: 28.0 × 30.5 × 16.5 cm
        2)Temperature range: room temperature above 8 ℃-425℃
        3)Temperature setting accuracy: 1℃
        4)The fastest heating rate: 75 ℃/min
            50-70°C, heating rate: 75°C/min
            70-115°C, heating rate: 45°C/min
            115-175°C, heating rate: 40°C/min
            175-300°C, heating rate: 30°C/min
            300-425°C, heating rate: 20°C/min
        5)The longest running time: 999.99 minutes
        6)Program temperature: 5 order
        7)Temperature accuracy: 1 ° C per room temperature, temperature fluctuation of<0.01 ° C
        8)oven temperature program Accuracy: ≤ 2%:≤2%
        9)Program temperature reproducibility: ≤1%:≤1%
    2.Heating Area
        1)Independent heating zone, excluding the column oven: 5 (two inlets, another detector, one auxiliary)
        2)Auxiliary area maximum operating temperature: 350 ℃
        3)Supports up to two heating valves
    3.Electronic airway control (EPC)
        1)EPC control is possible for all inlets and detectors
        2) Injection module::
              Pressure control accuracy: 0.01 psi psi
             Flow sensor accuracy:< ± 5%
              Detector Module Accuracy: 8%
    4.Inlet:
        1)Up to two inlets can be installed
        2)Mountable: packed column inlet and split / splitless inlet
    5.Fill column inlet::
        1) Electronic flow control
        2)Maximum operating temperature 400 ° C
        3)Maximum flow:< 100 mL/min
        4)To accommodate 1/4 inch and 1/8 inch packed columns and 0.530 mm capillary columns
    6.Split/splitless inlet (S/SL)
        1)Electronic pressure / flow control
        2)Maximum operating temperature 400 ° C
        3)Pressure range: 0 to 60 psi
        4)Maximum split ratio: 250: 1
        5)Total flow setting range: N2: 0 ~ 200 mL / min; H2 or He: 0 ~ 1250 mL / min;H2或He:0~1250 mL/min
3、 Near Infrared Spectrometer
 
Brand Model: Ocean Optical Flame-NIR
Introduction to parameters:
Detector response range: 900-1700 nm
Wavelength range: 950-1650 nm (preconfigured model)
Optical resolution: ~ 10 nm FWHM (25μm)
Signal to noise ratio: 6000: 1 (full signal)
Dynamic range: 6000: 1 (single acquisition)
Thermal stability: 0.08 nm / ° C
Scanning frequency (max): ~ 400Hz
Integration time: 1 ms → 65 s
Pixels: 128
Size: 89.1 mm x 63.3 mm x 31.9 mm
(34.4 mm with pad)
Weight: 265 g
4、 Microscope
 
Brand Model: LEICA DM4M:LEICA DM4M
Parameters:
Metallographic microscope
Modular design, can achieve reflection observation, transparent reflection observation configuration
Achromatic optical path, the overall optical path supports 25mm field diameter
6-hole objective lens turntable, with 32mm diameter industrial objective lens
Observation mode can be realized bright field, dark field, polarized light, interference
5、 Autocorrelaton Function Analyzer
 
Brand Model: APE Company Pulsecheck USB50
Parameters:
PulseCheck USB 50/measurable pulse width:<50Fs-12PS